Well pump size by depth
How much pump a house needs depends on two things: the flow its bathrooms call for at peak, and how far the pump has to lift and push. This table reads the smallest Goulds 10GS model that meets each household demand at each pumping level, on a 40/60 switch.
| Pumping level | 1 bath (7 gpm) | 1½ bath (10 gpm) | 2–2½ bath (14 gpm) | 3–4 bath (17 gpm) |
|---|---|---|---|---|
| 60 ft | ½ hp | ½ hp | ½ hp | ½ hp |
| 100 ft | ¾ hp | ¾ hp | ¾ hp | ¾ hp |
| 140 ft | ¾ hp | ¾ hp | ¾ hp | ¾ hp |
| 180 ft | ¾ hp | ¾ hp | ¾ hp | ¾ hp |
| 220 ft | 1 hp | 1 hp | 1 hp | 1 hp |
| 260 ft | 1½ hp | 1½ hp | 1½ hp | 1½ hp |
| 300 ft | 1½ hp | 1½ hp | 1½ hp | 1½ hp |
| 380 ft | 1½ hp | 1½ hp | 1½ hp | 1½ hp |
— means no model in the 10GS series (½ to 3 hp, recommended 3 to 16 gpm) meets that flow at that depth on 40/60; a higher-flow series is needed. Flow needs above 16 gpm sit outside the 10GS recommended range.
How to use it
Start with the pumping water level from your well log or a pump test, add the height from the wellhead to the pressure tank and the pipe friction for your run, and read the row at or below that total. The calculator does the arithmetic and draws the head. The total dynamic head guide explains each part.
The 10GS series at a glance
Each motor size covers a band of depths. The chart lists a rating only where the pump is in its recommended range, so a bigger motor is not simply "more pump" at every depth — the larger models are not rated at shallow depths at all.
| Model | HP | Rated at 40 psi | Rated at 60 psi |
|---|---|---|---|
| 10GS05R | ½ | 20–60 ft | — |
| 10GS05 | ½ | 20–120 ft | 20–60 ft |
| 10GS07 | ¾ | 40–200 ft | 20–160 ft |
| 10GS10 | 1 | 60–280 ft | 20–220 ft |
| 10GS15 | 1½ | 140–420 ft | 100–380 ft |
| 10GS20 | 2 | 200–540 ft | 140–500 ft |
| 10GS30 | 3 | 280–740 ft | 220–700 ft |
Pumping level, not static level
The depth to read is where the water stands while the pump runs. A driller's log usually records both the static level and the level during a yield test; the second is the one to use. If only the static level is known, a pump test is cheaper than a pump that cannot keep up.